CVE-2026-3732

8.8

Tenda · F453

A stack-based buffer overflow in the Tenda F453 web interface allows remote attackers to trigger denial of service or arbitrary code execution via the cmdinput parameter in /goform/exeCommand.

Executive summary

A critical stack-based buffer overflow vulnerability in Tenda F453 firmware version 1.0.0.3 allows remote attackers to achieve code execution or service disruption.

Vulnerability

The vulnerability exists in the /goform/exeCommand endpoint, where the cmdinput parameter is passed to the strcpy function without sufficient length validation. This allows a remote, authenticated attacker to corrupt stack memory and potentially execute arbitrary code.

Business impact

Successful exploitation poses a severe risk to network infrastructure. By achieving remote code execution, an attacker could gain full control over the router, facilitate lateral movement into the internal network, or permanently disrupt critical connectivity. With a CVSS score of 8.8, this vulnerability represents a high-severity threat to organizational availability and confidentiality.

Remediation

Immediate Action: Since a specific patch is not currently available, administrators should restrict access to the device management interface to trusted internal segments only. If the device is exposed to the internet, disable remote management features immediately.

Proactive Monitoring: Monitor system logs for repeated crash events or suspicious POST requests directed at the /goform/exeCommand endpoint. Investigate any unusual traffic patterns originating from the router management IP addresses.

Compensating Controls: Implement a Web Application Firewall (WAF) rule to drop POST requests to /goform/exeCommand that contain excessively long strings in the cmdinput parameter. Ensure that the device is isolated behind a robust firewall to prevent unauthorized access to the administration interface.

Exploitation status

Public Exploit Available: Yes, a functional proof-of-concept exists as documented in the technical write-up published by the vulnerability researcher.

Analyst recommendation

Given the availability of a public proof-of-concept and the potential for remote code execution, this vulnerability requires immediate attention. Security teams must prioritize isolating affected Tenda F453 devices from external networks and strictly limiting management access until the vendor releases a security patch.

More Tenda CVEs

Sources

Originally found and disclosed by LtzHust (VulDB User), per the CVE Program record.