CVE-2026-4008
8.8Tenda · W3
A stack-based buffer overflow in the Tenda W3 router allows remote attackers to trigger memory corruption via the GO parameter in the /goform/wifiSSIDset endpoint.
Executive summary
A critical stack-based buffer overflow in Tenda W3 firmware version 1.0.0.3(2204) poses a severe risk of unauthorized system disruption or remote code execution.
Vulnerability
This vulnerability is a stack-based buffer overflow occurring within the /goform/wifiSSIDset handler. An attacker with low privileges can trigger this memory corruption by sending a specially crafted POST request containing an excessively long value in the GO parameter.
Business impact
Successful exploitation of this flaw can lead to a complete compromise of the affected network device. Given the CVSS score of 8.8, the impact is considered high, as it could allow an attacker to crash the device, causing denial of service, or potentially execute arbitrary code to gain unauthorized control over the router and intercept network traffic.
Remediation
Immediate Action: Contact Tenda support or check the official Tenda website for firmware updates addressing this buffer overflow. If no patch is currently available, restrict administrative access to the device to trusted management interfaces only.
Proactive Monitoring: Inspect system logs for unusual POST requests directed at the /goform/wifiSSIDset endpoint. Monitor for unexpected device reboots or service instability which may indicate attempted exploitation.
Compensating Controls: Implement a Web Application Firewall (WAF) or an Intrusion Prevention System (IPS) rule to inspect and drop incoming traffic containing malformed or excessively long parameters in the GO field.
Exploitation status
Public Exploit Available: Yes, a proof-of-concept is documented in the researcher write-up on GitHub.
Analyst recommendation
The severity of this vulnerability necessitates immediate attention, as it provides a direct vector for memory corruption on edge networking equipment. Administrators should prioritize applying vendor-supplied firmware updates as soon as they become available. In the absence of a patch, users must restrict access to the web management interface to prevent unauthorized users from interacting with the vulnerable parameter.
More Tenda CVEs
Sources
Originally found and disclosed by Svigo_o (VulDB User), per the CVE Program record.
- VDB-350531 | Tenda W3 POST Parameter wifiSSIDset stack-based overflow Vulnerability database entry
- VDB-350531 | CTI Indicators (IOB, IOC, IOA)
- Submit #769182 | Tenda W3 V1.0.0.3(2204) Buffer Overflow Third-party advisory
- Submit #769183 | Tenda W3 V1.0.0.3(2204) Buffer Overflow (Duplicate) Third-party advisory
- Related
- Exploit / PoC
- tenda.com.cn