CVE-2026-4553

8.8

Tenda · F453

A stack-based buffer overflow in the Tenda F453 router allows remote attackers to trigger memory corruption and potentially achieve remote code execution via the fromNatlimit function.

Executive summary

A critical stack-based buffer overflow vulnerability in Tenda F453 firmware version 1.0.0.3 poses a significant risk of remote code execution.

Vulnerability

The vulnerability exists within the fromNatlimit function of the /goform/Natlimit endpoint. An attacker with low-level privileges can supply an overly long page argument that lacks proper length validation, leading to a stack-based buffer overflow.

Business impact

Successful exploitation of this flaw allows an attacker to execute arbitrary code or cause a denial of service on the network device. Given the device's role as a router, compromise could lead to full network control, traffic interception, or the permanent loss of connectivity for the affected environment. The CVSS score of 8.8 reflects the high severity of this remote, memory-corruption-based vulnerability.

Remediation

Immediate Action: Contact the vendor or check the official Tenda support portal for firmware updates addressing this buffer overflow. If no patch is available, isolate the affected device from the public internet immediately to prevent remote exploitation.

Proactive Monitoring: Monitor network traffic for anomalous HTTP POST requests directed toward the /goform/Natlimit endpoint, specifically looking for unusually long string payloads in the page parameter.

Compensating Controls: Deploy a Web Application Firewall (WAF) or an Intrusion Prevention System (IPS) rule to inspect and block excessively long inputs sent to the /goform/Natlimit URI.

Exploitation status

Public Exploit Available: Yes — a public proof-of-concept is available via the researcher's published technical write-up on GitHub.

Analyst recommendation

This vulnerability presents a severe risk due to the potential for remote code execution on edge network infrastructure. Administrators should prioritize the identification of all Tenda F453 units within their network and restrict management access to trusted internal subnets. Given the confirmed existence of a public proof-of-concept, users must remain vigilant and apply any vendor-supplied firmware updates immediately upon release to mitigate the threat of compromise.

More Tenda CVEs

Sources

Originally found and disclosed by LtzHust (VulDB User), per the CVE Program record.