CVE-2026-73173
8.8Advantech · EKI-1242EIMS / EKI-1242IEIMS
A missing authentication vulnerability in the Advantech EKI-1242 series allows unauthenticated remote attackers to execute critical management functions via TCP port 5058.
Executive summary
A critical authentication bypass in the Advantech EKI-1242 series firmware allows remote, unauthenticated attackers to perform unauthorized device management, including full system resets and firmware modifications.
Vulnerability
The vulnerability is defined as CWE-306, where the edgserver management protocol fails to perform required authentication checks. An unauthenticated attacker can send crafted packets to TCP port 5058 to trigger administrative operations like network reconfiguration, device reboots, and firmware upgrades.
Business impact
The ability for an unauthenticated remote actor to modify network configurations or force a firmware upgrade presents a severe risk to operational continuity and system integrity. Because this vulnerability grants full control over device management functions, it could be leveraged to brick devices, facilitate man-in-the-middle attacks, or provide a foothold for lateral movement within industrial networks. The CVSS score of 8.8 reflects the high potential for significant impact on system availability and integrity.
Remediation
Immediate Action: Consult the official Advantech Security Advisory provided in the references to determine if a firmware patch is available for your specific deployment and apply it immediately.
Proactive Monitoring: Monitor network traffic for any unauthorized communication directed at TCP port 5058 and correlate these events with unexpected device reboots or configuration changes.
Compensating Controls: Implement strict network segmentation and firewall rules to restrict access to TCP port 5058, ensuring that only known, authorized management workstations can communicate with the affected devices.
Exploitation status
Public Exploit Available: Unknown
Analyst recommendation
Given the high CVSS severity and the critical nature of the affected device management protocols, organizations must treat this vulnerability with extreme urgency. Administrators should prioritize identifying all vulnerable Advantech units within their environment and applying the vendor recommended firmware updates as soon as they become available. Until patches are applied, network-level access controls to the management interface must be enforced to mitigate the risk of unauthorized remote command execution.
More Advantech CVEs all →
History
- Disclosed CVE record published
- Collected by CVE Brief via github
- Analyst report written
- Published in the daily brief high section
Sources
Originally found and disclosed by Simone Bossi at Nozomi Networks, per the CVE Program record.